4.1 Notes on Selecting the Installation Location

This product is designed for the following environment.

• Indoor and outdoor installation • Ambient temperature: —20 to +60°C

• Altitude: Up to 2000m

• Humidity range: 10 to 90%(no condensation)

• Regulation of power voltage: ± 10%

• Pollution degree 2

• Structure: IP67 (NEMA 4X)

Do not store or install the flowmeter in :

1. Places within the immediate proximity of equipment producing electrical interference (such as

motors, transformers, radio transmitters, electrolytic cells, or other equipment causing

electromagnetic or electrostatic interference).

2.

Places where there is direct sunlight.

3.

Places where excessive vibration or mechanical shock occurs.

4.

Places where high temperature or high humidity conditions obtain.

5. Places where corrosive atmospheres obtain.

6.

Places submerged under water.

7. Place where there is slop floor. To put the flowmeter temporarily on the floor, place it

carefully with something, such as stopper, to support it so that the flowmeter will not

topple over.

8.

Places of too great an elevation or constricted areas where clearance for installation or

maintenance work is not provided.

9.

The standard length of the cable that connects the detector and converter is 30m. Select the

converter installation location so that the distance of the detector and converter will not exceed

LF602F 30m.

10. Places where there is following factors.

♦ Factors to impede infrared switch to operate properly

• Intense light such as direct sunlight and reflected sunlight by window glass or metal plate
• Place where brightness changes always such as ON/OFF of lighting
• Dense smoke or steam near the control panel

• Those attached on the control panel such as rain (dew drop), snow, ice, mud and oil, and haze due

to their attachment

• Light reflecting object near the control panel, or reflecting object such as metal plate placed

opposing to the control panel

When any of above factors is considered, take a measure for the proper operation of infrared switch
such as to place a cover or to secure a space for at least a person to stand in front of the control
panel.

When unable to avoid above factors, operate the EMF converter removing the factor by covering

the control panel by hand so that light does not shine on it, by cleaning those attached on the control
panel, or by standing in-between the reflecting object and the control panel to block the light.

-