6 password setting, To check the password, Toshiba – Toshiba LF600F User Manual

Page 64

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TOSHIBA

i6,F,8,A0,8,6,9,

8.2.6 Password Setting

The password function is provided to protest the settings and adjustment of the functions affecting
the flow rate measurement. See 7.4 ‘^Conflguration Items Selection Table” for limited functions.

Proceed as follows to check or change the password.

• To check the password:

Key operation

Display example

Description

A:

MEAS MODE

EX CURRENT
METER SIZE
EX FREQ

FLOW DIRECTN

^PASSWORD

ADDRSET

[SEL] [ENT]

Select "PASSWORD" in the configuration item

selection screen.

A5:

PASSWORD

123

The currently set password is displayed.

[ENT]

[EXT] [ENT]

[EXT]

A:

MEAS MODE

^EX CURRENT

METER SIZE
EX FREQ
FLOW DIRECTN
PASSWORD

ADDRSET

_[SEy_______

W

________

You return to the configuration item selection

screen.

* However, if a wrong password is entered when the mode is changed from the measuring mode to

the setting mode, *** appears.

Key operation

Display example

Description

A5:

PASSWORD

The currently set password is displayed as ***.

[ENT]

IEXT1 [ENTI

63

-

Advertising
This manual is related to the following products: