Toshiba – Toshiba LF600F User Manual

Page 57

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TOSHIBA

6,F,8,A0i8|6,9,

Key operation

Display example

Description

STEPS

A1:

EX CURRENT

0.21|0

Repeat this operation to change the setting value to

0.2150A.

[SEL]<=>[UP]

A

fU P] [SEL] fSETl

When the value changes to the desired value, press

the [SET] key to set the numeric value temporarily.

STEPS

A1:

EX CURRENT

0.2150

Pressing the [SET] key displays a message asking

you to confirm whether the setting is OK.

If OK, press the [SET] key. If you need to redo the

[SET]

A

OK?^

fNOl fSETl

setting, press the [NO] key.

STEP7-1

[NO]

A1:

EX CURRENT

B.1900

A

fU P] iSELl [SET]

Pressing the [No] key when you are asked "OK?"

causes the numeric value to return to the previous
value and enables you to redo the setting.

STEP7-2(=END)

A1:

EX CURRENT

0.2150

Pressing the [SET] key when you are asked "OK?"

causes the setting value to be determined.

Then if you press the [EXT] key, you return to the

[SET]

A

[EXTl [ENTl

menu screen.

If you press the [ENT] key, you can restart electric

current value change operation from a state of

0.2150A.

(Note) The exciting current value must be a value from O.OOOOA and 0.2500A.

If you set an exciting current value higher than 0.2500A, *HIGH OVER SPEC,* is displayed

and the set value is returned to the value before change. In this case you have to set a value

once again.

-

56

-

Advertising
This manual is related to the following products: