i6,F|8A0.8,6,9,

8.2.14 Damping Constant

The damping constant is used to moderate output fluctuations. (The larger the damping constant, the
more the output is averaged. But the response to an input change will be slower.) The damping
constant can be set as follows:
The damping constant is set for 0.0 sec, 0.5 sec and 1 to 60 sec (in increments of 1 second)
Note: 0.0 sec setting will work as equal to 0.1 sec damping constant.

Set 1 sec or more for normal operation.

If you set a value exceeding 60s, it is forcibly changed to 60s before data is written.
Proceed as follows to check or change the damping constant.

Shown below is an example of changing the damping constant from 0.0s to 10s.

Key operation

Display example

Description

D:

MEAS MODE

-»DAMPING

LOW CUT

ALM mA SET

DSP LOW CUT

LOW LIMIT

[SEL] [ENT]

Select "DAMPING" in the configuration item

selection screen.

STEP1

D1:

DAMPING

02.0

The currently set damping constant (2.0s in this example)

is displayed.

[ENT]

s

lEXTl iENTl

Then press the [ENT] key.

* Pressing the [EXT] key returns you to the menu screen.

STEP2

D1:

DAMPING

02.0

The switch name display at the bottom changes (three

keys [UP], [SEL] and [SET]).

At the same time, the cursor appears.

[ENT]

s

[U P] fSELl fSETl

(The digit on which the cursor is positioned is

reverse-displayed.)

STEP3

[SEL]<^[UP]

D1:

DAMPING

iS.o

s

[U P] fSELl fSEH

Move the cursor to the desired digit using the [SEL] key

and change the numeric value using the [UP] key.

Repeat this operation until the value changes to 10.0 s.

When the value has changed to the desired value, press

the [SET] key to set the damping constant temporarily.

STEP4

D1:

DAMPING

10.0

When you press the [SET] key, a message

confirming you whether the setting is OK is

displayed.

[SET]

s

OK? ®

[NO] [SET]

If OK, press the [SET] key. If you want to redo the setting,

press the [NO] key.

STEP5-1

[NO]

D1:

DAMPING

E2.0

s

[U PI fSELl [SETl

Pressing the [NO] key when you are asked "OK?" causes

the damping constant to return to the

previous value and enables you redo the setting.

STEP5-2(=END)

D1:

DAMPING

10.0

Pressing the [SET] key when you are asked "OK?" causes

the setting to be determined.

Then press the [EXT] switch to return to the menu screen.

[SET]

s

____ ixi]__________

W

______

Pressing the [ENT] key enables you to restart damping

constant change operation from a state of 10.0s.

Note If you set a value exceeding 60s, it is forcibly changed to 60s before data is written.

-