Page 20 of 77

Butterworth
4th ord.

24
dB/
oct.

2

1.307

0.541

-

-

Linkwitz-
Riley
4th ord

24
dB/
oct.

2

0.707

0.707

-

-

Butterworth
5th ord.

30
dB/
oct.

3

1.618

0.618

0

-

Butterworth
6th ord.

36
dB/
oct.

3

1.932

0.707

0.518

-

Linkwitz-
Riley
6th ord.

36
dB/
oct.

3

1

1

0.5

-

Butterworth
7th ord.

42
dB/
oct.

4

2.247

0.802

0.555

0

Butterworth
8th ord.

48
dB/
oct.

4

2.563

0.9

0.601

0.51

Linkwitz-
Riley
8th ord.

48
dB/
oct.

4

1.307

1.307

0.541

0.541

5.

LowP = Low Pass Filter

20

50

100

500

1000

5000

10000

20000

-40

-36

-24

-12

-6

-3

0

2

Frequency in [Hz]

P

o

w

e

r

in

[

d

B

]

FilterType = 'LowP' (Lowpass) Freq = 1000Hz

Q = 0.707

Butterworth 1.Ordnung

Q = 0.2
Q = 0.5

Linkwitz-Riley 2.Ordnung

Q = 0.707 (default) Butterworth 2.Ordnung

This example shows various low pass filters at 1000Hz, which are characterised by
different Q-factors.