Functions of the menu items under ‘out, 7 functions of the menu items under ‘out – KLING & FREITAG K&F CD 44 Digital System controller User Manual

Page 33

Advertising
background image

User's manual

K&F CD 44 Digital System Controller

KLING & FREITAG GMBH © 2014

Version 11.6

Page 33 of 77

With this, you can load different EQs in addition to a setup (i.e. same use at different
locations).

Load

Used to load named EQ setups.

Select the desired setup (position indicator) by turning and pushing the knob.

Edit

Used to edit named EQ-Setups.

Here you can edit the 31 bands of the one-third-octave band equalizer.

Furthermore, you can set the EQ to Bypass . With the setting Bypass, the EQ is by-passed
and thus does not influence the signal. This function is, for example, advisable when
evaluating the before/after effect when editing the EQs.

Reset

Used to return all settings in the current EQ setup back to zero. This is advisable if, for
example, you are going to create a new EQ setting.

Save As

Used to save the changes in named EQ setups.

To save a new EQ setup activate <In » Input> through <Input4 » EQ 31-Band » Save
As> (turn and push the knob). Select <new> by turning the knob, push the knob
twice, and select the first letter or number by turning the knob. If the desired letter
or number is shown, then verify the entry by pushing the knob. The position indicator
automatically jumps to the next letter or number. Continue as described above until
you have written the desired name.
By pushing the EXIT button, you will save the setup under the name you have
defined.

To save changes in a previously existing EQ setting, activate <In » Input1> through
<Input4 » EQ 31-Band » Save As>. The position indicator is on the EQ setting that you
just edited. Pushing the knob saves the change.

Delete

This function is used to delete named EQ settings. It is accessible at <In » Input1 » EQ 31-
Band only>.

<In » Input1> through <Input4 » EQ 31-Band>

Gain (input)

See chapter 'Input and Output Gains' on page 23.

Delay (input)

See chapter 'Input and Output Delays'on page 24.

<PEQ » Filter 1> through <Filter 4> (easier to access with 'Filter A Button'). EXIT

See chapter 'Parametric Filters PEQ' + SEQ LShelv' on page 15.

7.5.7

Functions of the Menu Items under ‘Out’

This is where you can make the possible adjustments for the output signals. Four outputs are
available (<Out » Output1> through <Output 4>):

1.

Select LS-Block

This is the position where the controller is informed which Kling & Freitag speaker is
connected to which output. The controller then loads the parameters for the speaker-
specific:

adjustment of the volume level (gains) for the optimal connection of the K&F
subwoofers to all listed K&F tops.

filters for optimising the frequency response and the feedback prevention.