Testing the scanner 7-5, Testing the scanner -5 – Avery Dennison 6035 Equipment Manual User Manual
Page 60

2. Insert the loopback plug and press any key (except b) to
start the test. Press b to exit.
3. When the test finishes, you will see
Press Esc to cont.
Testing speed: XX
Testing parity: XX
Testing ctrls: XX
where XX is OK or err.
Press b
to exit.
If the printer fails to send or receive data, please make a note and
call Service.
Te s t i n g t h e S c a n n e r
The Scanner diagnostic function provides the following selections:
Trigger Scanner
Displays scanned bar code values for
successful scans or no data for scan failures.
Configuration
Allows the user to enable or disable scanner
features for specific bar code types, low
power mode, and time-out mode.
To test the scanner:
1. At the Main menu, scroll with the arrow keys until you
highlight Scanner. Press e
. You will see:
Select scanner test
Trigger scanner
Configuration
About
D
2. Scroll with the arrow keys until you highlight the scanner test
you want. Press e
. Press
b
to exit.
Using Diagnostics 7-5
TC6035EZEM Rev. C 10/98