To run the Black Mark test:

1. From the Sensors sub-menu, scroll with the arrow keys until

you highlight Black Mark. Press e

.

When the black mark is not positioned over the sensor, you
will see:

Black Mark = ###
White

Values must be greater than 480.

When the black mark is positioned over the sensor, you will
see:

Black Mark = ###
Black

Values must be less than 288.

If the value is invalid, make a note and call Service.

2. Press b

to exit.

The values displayed may fluctuate

on the screen.

Using Diagnostics 7-15