Operation – Beisler 1265-4 User Manual

Page 34

Advertising
background image

Operating Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

B-24

B.3

Operation

B.3.9 Sewing process

Trousers panels and knee linings are stocked on the trays.

Starting the automatic machine cycle:

1. Select the seam at the operating panel.

2. Place trousers panel and knee lining on top of each

other with the hems being flush. The sequence de-

pends on the selected sewing program.

3. Fig. 20: Slide trousers panels below the contour

guide sliding shield 1 all the way to the stop, align

hem flush with the sewing stop 4 at the sewing

head. Smoothen sewing pieces.

4. Pull seam start point 2 of trousers panels to the

pressure foot just before the photocell reflection point

3.

5. Then, slide the trousers panels into the sensor range

of the photocell 5. When the fabric interrupts the

light beam at the reflective surface, the automatic

machine cycle is started automatically. The seam is sewn and serged.

NOTE - Starting the sewing process

To ensure the correct routing of the seam, the trousers pa-

nels must be released as soon as the transport unit of the se-

wing head has seized the sewing pieces.

NOTE - Resetting the insertion process

Before the response delay period of the photocell has elapsed,

the insertion process can be cancelled by moving the trou-

sers panels out of the sensor range of the photocell.

After the sewing process has started, the machine cycle can

only be cancelled by pressing the program stop switch or by

pressing the function key F1.

Creating identical stitch images:

If identical stitch images are required for inseams and side seams, the knee

lining must always be lined up in the same position (always top or always

bottom). In this case, the trousers panel is lined up alternatingly flush with

the waistband and flush with the hem.

• At the waistband side, the sewing process is started by photocell 13 at

the sewing head.

• At the hem side, the sewing process is started by photocell 15 which

is integral to the tray. The length of the sewing distance from the be-

ginning to the end of the knee lining is determined by the setting in the

program control.

Fig. 20

Advertising