Programming – Beisler 1265-4 User Manual

Page 81

Advertising
background image

D-18

Programming Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

D.3

Programming

Functions on access level 2

The function keys on access level 2 are assigned to the symbols that

are shown on the display. These symbols are only visible when access

level 2 has been selected. They are displayed inverted when the machi-

ne function that they represent has been disabled in the marked seam

of the sewing program.

BD":z!FH

abcdefgh

F1 List of basic parameters

F2 Activate / deactivate the seams of a sewing program

F3 Enable preseams

F4 Set start mode

F4 Activate machine manually

F6Activate C machine (optional) manually

F7 Reset the day counter to zero

F8 Display inputs / outputs

Basic parameters

Basic parameters are values that control the basic functions of the ma-

chine. Changes to basic parameters will affect all stored sewing pro-

grams.

NOTE - Modifications of basic parameters

The basic parameters of the machine have been fitted at

the factory to match one another perfectly. Improper modi-

fication of the values can impair the processing quality or

even damage machine components.

1. Request the basic parameter list:

B

• Press the a key.

2. To move up or down in the parameter list:

• Press the § or $ key.

3. Activate the parameter input field:

• Press the % key.