Programming Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

D.3

Programming

4. Change the value:

• Press the & or / key,

or enter a two-digit or three-digit value using the numeric keypad. In-

put sequence: Hundreds digit, tens digit, units digit.

5. Confirm input:

• Press the ( key.

6. Exit menu and return to access level 2:

• Press the ( key.

7. Return to access level 1:

• Press the ( key.

The following basic parameters can be modified:

01 PHOTOCELL REACTION TIME

Delay between insertion process (photocell darkens) and beginning

of sewing

02 PHOTOCELL -> FOOT DOWN

Duration before pressure foot is lowered and the sewing process

starts (this setting depends on the sewing material)

03 THREAD TENS. CLOSE/BEGIN

Number of stitches while the top thread is slackened before being

retensioned

04 CHAIN CUT.SUCTION (BEG.)

Legth (in cm) for the chain cutting function at sewing start, longer

suction period required for three-thread machines; switch-off for sa-

ving energy

05 CHAIN OFF STITCHES

Distance for postsewing stitches when the sewing piece is removed

from the sewing unit during the sewing process (e.g. for chain sepa-

ration)

06 CHAIN CUT.SUCTION (END)

Duration of chain cutting function at end of seam; switch-off for sa-

ving energy

07 THREAD TENSION OPEN/END

Number of stitches while the top thread is slackened at the end of

the seam

08 PHOTOCELL BLOCKED (END)

Time delay for insertion of new sewing piece (blocking period after

photocell brightens)