Programming

Input / output test

You can use this function for selecting the inputs and outputs of the ma-

chine control for troubleshooting and for testing individual machine ope-

rations.

The outputs (OUT) are selected and tested separately. The correspon-

ding inputs (INP) are displayed for the active outputs.

Additionally, the selected output can be switched intermittently.

Activated inputs / outputs are marked with highlighted numbers.

INP:

01 02

03

04

05

06

07

08

09

10

11 12

13

14

15

16

17

18

19

20

21 22

23

24

25

26

27

28

29

30

31 32

33

34

35

36

37

38

39

40

41 42

43

44

45

46

47

48

49

50

51 52

53

54

55

56

57

58

59

60

OUT:

01 02

03

04

05

06

07

08

09

10

11 12

13

14

15

16

17

18

19

20

21 22

23

24

25

26

27

28

29

30

31 32

33

34

35

36

37

38

39

40

41 42

43

44

45

46

47

48

49

50

51 52

53

54

55

56

57

58

59

60

1. Select function for resetting inputs / outputs:

H

• Press the h key

2. Select number line:

• Press the § or $key

3. Mark output number by moving the cursor in front of the correspon-

ding function number. The cursor now has the shape of an arrow.

• Press the & or / key.

4. Activate output:

• Press the % key.

The output number is highlighted in black. The output is active.

5. Deactivate output:

• Press the % key.