Service Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

C-4

C.2

Location requirements

C.2.1 Floor quality

The floor of the room where the machine is to be installed must have a

sufficient surface strength. The location of the machine must be free of

vibrations.

If several machines are to be installed in one room, the static load bea-

ring capacity of the ceiling must be considered.

Weight:

• Machine with accessories approx 120 kg

C.2.2 Interior climate

Climatic requirements for the operating room:

The machine must only be stored or operated in closed operating

rooms.

• Room temperature

+10° C to +45° C

• Relative humidity

max. 80 %

C.2.3 Floor space requirements

For operation during production and for service works, the machine

must be freely accessible from all sides. On all sides, there must be a

minimum clearance of 1 m.

Dimensions:

• L x W x H

2300 x 1500 x 1700 mm

NOTE - Electromagnetic interference

The machine must not be installed in the immediate vicini-

ty of devices or electrical components (e.g. transformers)

generating a strong magnetic field as otherwise the cor-

rect function of the program control may be impaired.