Troubleshooting – Beisler 1265-4 User Manual

Page 62

Advertising
background image

Service Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

C-26

C.6

Troubleshooting

Error message

Cause

Correction

Photocells not bright: 13;
15; 16

Photocell does not respond to light
change

Adjust photocell properly; reflective
surface dull, clean as necessary;
replace photocell

I/O communication error

Error during data transmission between
control and I/O module

Check all cable connections (flat ribbon
cables) to 9020013 /. 9020024; if
required, replace contol module 9020013
or module 9020024

ES 02

Photocell 15 missing

Connect photocell 15,
remove link at X24-Pin2

Thread breakage at sewing
head

Sewing machine thread monitor has
responded

Pass thread through needle

Error 45-49:
I/O RES

Internal hardware error during data
transmission

Replace adapter PCB 9020013 –
9020020