Programming

Diagnostics

The DIAGNOSTIC menu contains service functions for testing machine

assemblies and initiators that control them.

1. Select the programming menus:

• Press the ( key.

2. Select the DIAGNOSTIC function:

• Press the c key.

3. Select the test functions:

NOTE - Diagnostics functions

These service functions should only be performed as in-

structed by the Service Department of Beisler GmbH or in

cooperation with experienced service personnel members.

CAUTION - Damage to the machine!

During these tests, individual machine assemblies or ma-

chine cycles are started. If components are partially or

completely removed, machine components may be dama-

ged. Perform tests only when the machine is at operating

temperature!

F1 SERVICE TESTS

These menus are only accessible after the service code has been

entered and must only be selected as instructed by authorized ser-

vice personnel members.

F4 MAIN HEAD TESTS

F5 C-HEAD TESTS

These functions are used to check the sewing motors and the pertai-

ning stepper motors for the sewing and transport units. The test rou-

tines are identical for the sewing head and for the C machine. The

menu C-HEAD TESTS merely contains a routine that controls the

sewing motor.

F1 SEWING MOTOR CONTROL

The nominal speed of the stepper motor is compared to the actu-

al motor speed.

1. Enter the desired speed at the numeric keypad.

2. Confirm input and start measurement:

• Press the %

key.

The motor starts running, the actual speed is measured and displayed.

Advertising