Nozzle position calibration
The nozzle position calibration is a two-point calibration to adjust the position feedback for the nozzle position. Nozzle
calibration should be performed at installation and any time that cut quality decreases.
To begin calibration verify that the main menu (shown below) is displayed on the laser head controller screen and follow
the steps outlined below.
Nozzle extension at 0 mm
Continued on the next page
Push to Select
+
=
Configuration
screen
Push to Select
+
=
Calibration
screen
Push to Select
+
=
Nozzle
extension
screen 1
Rotate the nozzle extension until it is fully retracted to the main
body of
the cutting head.
LHC Ver: 1.13
LPC Ver: 1.17 P2
<Calibrate>
<Diagnostics>
<Setups>
<Back>
Laser power 1500W
O2
12 PSI
Beam
OFF System
OK
Calibrate Nozzle Position
Calibrate CHS Position
<Back>
Move Nozzle Extension to 0 mm
Push Rotary Wheel when at position