1. Open the fiber laser supply enclosure front door and
locate the E-Stop switch assembly.
Emergency stop (E-Stop) switch installation
2. Remove the actuation knob and lock-nut from the
E-Stop switch assembly.
Lock nut
Press and twist the knurled area
E-Stop switch assembly location
Actuation knob
Lock nut
Switch
3. Place the actuation knob into the “EMERGENCY
STOP” mounting hole on the top of the fiber
laser supply enclosure, and use the lock nut to
secure the E-stop actuation knob to the top of the
enclosure.
4. Align the switch’s contact base thumb ring with the
arrow on the actuation knob and press.
Emergency stop mounting hole