Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 130

setup and OperatiOn
3-22
Hypertherm Fiber Laser
Instruction Manual – 807090 Revision 3
Nozzle extension at 18 mm
Nozzle
extension
scale
Indicator
mark
The calibration will fail if the controller does not detect a large enough voltage change, between the 0 mm and 18 mm
nozzle extension positions.
Continued from the previous page
Calibration
result
Push to Select
+
=
Push to Select
+
=
If the calibration was successful, the following message is displayed. The parameters will vary slightly for each system.
If there was a calibration error, the following message is displayed.
Nozzle
extension
screen 2
Move Nozzle Extension to 18 mm
Push Rotary Wheel when at position
Nozzle Position Calibration Complete
Scale Factor = 553
Push select to accept new value
Calibration Error! Loading Defaults
Scale Factor = 500
Push select to accept new value
Move Nozzle Extension to 18 mm
Push Rotary Wheel when at position
Move Nozzle Extension to 0 mm
Push Rotary Wheel when at position