Connect the power, Connect the power -48 – Hypertherm HyIntensity Fiber Laser Rev.3 User Manual
Page 96

InstallatIon
2-48
HyIntensity Fiber Laser
Instruction Manual – 807090 Revision 3
Connect the power
1. Insert the power cable through the strain relief at the rear of the fiber laser supply.
2. Open the rear door of the fiber laser supply enclosure and locate the main power terminal block.
3. Connect the power leads to the terminals as shown below.
4. verify that the line disconnect switch is in the OFF position and remains in the OFF position for
the remainder of the installation of the system.
5. Connect the power cord leads to the line disconnect switch following national and local electrical codes.
Wire colors
L1 = Red
L2 = White
L3 = Black
(PE) Earth ground = Green/yellow
1 L1
3 L2
5 L3
Line disconnect
switch
Power cable
Ground
Red
White
Black
DANGER
ELECtRICAL SHOCK CAN KILL
t
he line disconnect switch must be in the OFF position before making the power cable connections.
In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries,
follow appropriate national
and
local safety procedures.