4 calculated data, Alculated data – K-Patents SeedMaster 2 User Manual

Page 16

Advertising
background image

3 THE SEEDMASTER 2 CRYSTALLIZATION TRANSMITTER …

16

16

Data base

START

On-line inputs

program once

Parameters

every 10 sec

Digital I/O
Calculated outputs
Archive data

Strike
ACTIVE?

ACTIVE

YES

STAND-BY

MODE

MODE

Calculations

operations

Archive

END

data

Seeding
operations

Decision based on
THIRD INPUT

MASS. DENSITY MASS. SOLIDS CONT. MOTOR CONS. LAB. CR. CONT.

Calculations

Calculations

Calculations

Calculations

END

Fig. 3.4 The basic SeedMaster 2 operations

Based on the calculated data SeedMaster 2 can be programmed to carry out automatic seeding of the
crystallizer on its own, when

supersaturation, or

massecuite density

becomes equal to the supersaturation or density set-point selected by the technologist or pan operator.
Actual seeding is carried out by opening the seed valve (digital output) for a pre-set time interval.
If seeding of the crystallizer is carried out not by SeedMaster 2, but by another device (a control system, for
example), or by the operator, SeedMaster 2 must be notified accordingly by a digital input, or via digital
communication.
All operations discussed above can be performed independently with two crystallizers at the same time.

3.4 Calculated data


Based on the information received SeedMaster 2 carries out involved calculations on-line. These, and one or
the other of the measured data used (density, solids content, motor consumption, or laboratory crystal
content data) are combined providing information on 7 massecuite parameters (set of massecuite
parameters) per crystallizer. These are: