K-Patents SeedMaster 2 User Manual

Page 47

Advertising
background image

7 CONFIGURE SeedMaster 2

47

47

CONFIG. -> 3RD INPUT -> MOT. CONS.

1 /

SINGL E

M. CONS. (PH. 1 END)

KEYBOARD

KEYBOARD 3 . 3 kW

CR. CONT. (PH. 1 END)

KEYBOARD

KEYBOARD 2 5 %

MOT. CONS. (STRIKE END)

KEYBOARD

KEYBOARD 7 . 1 kW

LEVEL MEAS.

KEYBOARD

KEYBOARD YES

PAN MAX. LEVEL

KEYBOARD

KEYBOARD

7 7

%

CONC. (REFR., PH.1 END)

KEYBOARD

KEYBOARD

8 0 . 2%

PREV.

ACCEPT

BACK

1 / 2 SPEED

ACCEPT

CHANGE

BACK

ACCEPT

Fig. 7.9: The first page of configuration
NOTE:
1. All parameters can be entered by manual entry (KEYBOARD), or via digital data communication.
2. CR. CONT. (PH. 1 END) and FEED SYRUP PURITY have to be entered in Set-up -> Inputs.

Depending on the answer given to the first question (1 / 2 SPEED) naming of some parameters may be
different.

MOTOR: SINGLE SPEED

Parameters:

Range:

Notes:


1 / 2 SPEED

SINGLE (single speed motor, see Fig. 7.7)

MOT. CONS. (PH. 1 END)

0 < VALUE

Motor consumption at PHASE 1 END

must be larger than zero (A, or kW).

CR. CONT. (PH. 1 END)

10 – 45 %

This is the laboratory crystal content at

PHASE 1 END. Typical value: 25 % by

volume (point 2 in Fig. 7.7).

MOT. CONS. (STRIKE END)

0 < VALUE

Motor consumption at the end of the

strike, must be larger than zero (A, or kW).

LEVEL MEAS.

YES /NO

Level measurement is optional. If the answer

was NO, then instead of LEVEL data CR.

SIZE (mean size) will be displayed on the

MAIN DISPLAY.

PAN MAX. LEVEL

40 – 100 %

Only if YES was selected above.

CONC. (REFR., PH. 1 END)

65 – 95 %

Concentration measured by the refracto-

meter at PHASE 1 END.

CONC. (REFR., STR. END)

65 – 95 %

Concentration measured by the refracto-

meter at the end of the strike.

TEMP. (REFR., PH. 1 END)

30 - 85

˚C

Temperature measured by the refracto-

meter at PHASE 1 END : only if the motor

operates with SINGLE speed.

TEMP. (REFR., STRIKE END)

30 - 85

˚C

Temperature measured by the refractometer

at the end of strike or cooling crystallization.

CR. CONT. (STRIKE END)

0 - 60 %

Crystal content at the end of the strike

(% by volume). It must be specified in

Set up -> Inputs, and can not be entered

or modified here.

SEED CRYSTAL SIZE

0.005 – 1,5

If shock, or full seeding is practiced 0.01

mm is typical. The range covers the typical

values when crystal footing (magma) is used

for seeding.

PRODUCT CRYSTAL SIZE

0.03 - 6

Size in mm.

LENGTH OF CRYST. TIME

30 – 420 min

Length of the real time of crystallization

(from seeding to the end) in minutes. After the

1

st

strike the time of the last crystallization can

be accessed by going to DISPLAY -> TEST -

> OTHER DATA

Advertising