6 test data, Test, Data – K-Patents SeedMaster 2 User Manual

Page 73

Advertising
background image

10 DISPLAY

73

73

The OUTPUT column lists the number of serial (COMX.), digital communication (COMM.) and Standard
current (0-20 mA and 4-20 mA) outputs.
The SEEDING column provides information on the type of seeding selected (MANUAL, AUTO SUPS., or
AUTO DENS. With the selected SET POINT or commanded via COMMUNICATION).
SW. version X.X provides information on the software version used in the device.

10.6 TEST DATA


The TEST display is a tool to check the operation of SeedMaster 2 hardware and some of its software.

Analog input

1 / 0. 1

1 / 0 . 1

Menu

Trend

Menu

Analog input

Strike history

Analog output

Display

Standard display

Display

Digital I/O

System information

COMX ports

Test

Test

Other data
Events
Modbus reg.

a) b)

Fig. 10.10

DISPLAY -> TEST -> ANALOG INPUT

ANALOG INPUTS

AI_1 : 12.4 mA

AI_5 : 18.9 mA

AI_2 : 0 mA

AI_6 : 0 mA

AI_3 : 0 mA

AI_7 : 0 mA

AI_4 : 0 mA

AI_8 : 0 mA

BACK

Fig. 10.11

In Fig. 10.11 current (actual) analog (standard current) inputs from 2 transmitters (for example: 2 motor
consumption transmitters) are shown.

NOTE:
SeedMaster 2 has 8 analog inputs which can serve 2 instruments. If 2 pans are served, it is recommended to
reserve channels AI_1…AI_4 for instrument I1 and inputs AI_5…AI_8 for instrument I2, respectively, which
makes instrument identification and eventual addition of further inputs easier.