2 determining the local syrup parameters, 1 sample preparation for the saturation test, Etermining the local syrup parameters – K-Patents SeedMaster 2 User Manual

Page 91

Advertising
background image

12 APPENDECES

91

91

12.2 Determining the local syrup parameters

12.2.1 Sample preparation for the saturation test


A) Take 7-10 samples 100 g each from the same low-purity final molasses (green syrup) and determine
concentration, sugar content and purity data in the lab. Calculate non-sugar and water content, too. Put the
samples in vessels which can be well sealed later on in order to prevent evaporation or leakage.

EXAMPLE :

ORIGINAL SAMPLES :

SOL (g)

S (g)

Q (%)

NS (g)

W (g)

Gsample (g)

1

83,22

51,37

61,73

31,85

16,78

100,00

2

83,22

51,37

61,73

31,85

16,78

100,00

3

83,22

51,37

61,73

31,85

16,78

100,00

4

83,22

51,37

61,73

31,85

16,78

100,00

5

83,22

51,37

61,73

31,85

16,78

100,00

6

83,22

51,37

61,73

31,85

16,78

100,00

7

83,22

51,37

61,73

31,85

16,78

100,00


where :

SOL (%, g) : solids content (concentration)

S (%, g) : sugar content

Q (%) : purity = 100.S/SOL

NS (g) : non-sugar content = SOL - S

W (g) : water content = Gsample - SOL


B) Calculate the non-sugar to water ratio (NS/W) and enter it for sample No.1, which from now on will represent
the original sample with its original NS/W ratio. Select (NS/W)* values which will result in well distributed data in
the complete range from (NS/W)* = 0 to the original one.
Using the selected (NS/W)* and the original water content (W) calculate new water content (W*) and water to add
(Wadd) data for samples No.2-No.7.
NOTE : when (NS/W)* = 0, the saturation coefficient is always equal to 1.0.

SOL.(100 - Q)

NS/W = ----------------------

100.(100 - SOL)


W* = NS/(NS/W)* (g)

Wadd = W* - W (g)


EXAMPLE (continued) :

Selected

Calculated

range :

water :

(NS/W)*

W* (g)

Wadd (g)

1

1,90

16,78

0,00

2

1,6

19,91

3,13

3

1,2

26,54

9,76

4

1

31,85

15,07

5

0,7

45,50

28,72

6

0,4

79,63

62,85

7

0,2

159,25

142,47

8

0


Add the listed amount (Wadd) of pure water to each sample. Sample preparation is now complete.