Gpc plus wiring, Component & system wiring 73, Gpc plus controller – Orion System VCM Component User Manual

Page 73: Warning, Not used, Jumper setting, Filename date: description: page drawn by, 1 of 2 job name g-gpc-pluscntrl1a.cdr

Advertising
background image

Component & System Wiring

73

GPC Plus Wiring

1.)24 VAC Must Be Connected So

That All Ground Wires Remain
Common.

3.)All Communication Wiring To Be 18

Ga. Minimum, 2 Conductor Twisted
Pair With Shield. Belden #82760 Or
Equivalent.

4.)It Is Recommended That All

Controllers Address Switches Are
Set Before Installation.

2.)All Wiring To Be In Accordance With

Local And National Electrical Codes
and Specifications.

Line Voltage

All Communication Loop Wiring Is

Straight Through

24VAC

24VAC Transformer

10 VA Mini mum

GND

Local Loop RS-485

9600 Baud

Analog Inputs AIN1Thru AIN7

Can Be Used For 10kOhm

Type III Thermistor, 0-5VDC

Signal, 4-20mA Signal Or Dry

Contact Closure Inputs.

As Required.

Analog Input AIN6 Can Only Be Used

For Connection Of A Static Pressure

Transducer With Modular Connector

Connect To

Next Device On

The Local Loop

24VAC Power
For Relay Outputs

5 Relay Outputs Are
Available On Board For
On/Off Control Of
Equipment. When
Required 4 Additional
Relay Outputs Are
Available By Using The
Optional OE357 4 Relay
Output Expansion
Board. See Below.

Connect Tubing To High Pressure
Port (Bottom Tube) and Route To Static
Pressure Pickup Probe Located In Unit
Discharge. Leave Port Marked “Lo” Open
To Atmosphere

S.P.

Transducer

Splice If Req’d

Connect To
Expansion Board
Base (When Used)

4 Additional Relay Outputs
Are Available By Using The
OE357 4 Relay Output
Expansion Board. The
OE352 2 Slot Expansion
Base Board Is also
Required To Mount The
OE357 Board.

OE352 2 Slot Expansion Base Board

OE357
4 Relay Output
Board

Not Used

RL

Y1

D1

D2

D3

D4

D5

RAM

C3

C2

U6

PHILIPS

CX6

C1

CX2

U2

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

POWER

GND

24VAC

L1

D16

R6

C9

SC1

R1

1

U1

1

MC34064A

D13

C16

9936

VR2

TB4

R27

C13

R10

VR1

C19

C18

NE5090NPB3192

0PS

U8

CX8

U9

X1

R7

D10

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ3

PJ2

PJ1

EXPANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D18

D17

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-5

VDC

0-1

VDC

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y2

RL

Y3

RL

Y4

RL

Y5

CX15

(1 MEG)

HH

P1

C21

CX3

EPROM

U3

Warning:

24 VAC Must Be Connected So That All
Ground Wires Remain Common. Failure To
Do So Will Result In Damage To The
Controller

T To T, R To R, SHLD To SHLD

FILENAME

DATE:

DESCRIPTION:

PAGE

DRAWN BY:

GPC Plus Controller

1 Of 2

JOB NAME

G-GPC-PlusCNTRL1A.CDR

OE331-21-GPCPLUS

B. Crews

03/08/05

Note: When Using Sensors or

Transducers With 4-20 mA Input

Signal, The Pull-up Resistor For

The Input Being Used Must Be

Removed From The Controller

Board And A 250 Ohm Resistor

Must Be Wired Between The Input

Terminal And The Ground Terminal

On The Controller Board

Pull-up Resistor- Typical

Mini DIN Connector

For Connection Of Modular

Service Tool

OE331-21-GPCPLUS

GPC Plus Controller

VR5

MC

7824CT

C6

TB2

R14

D3

VR4

7812CT

MC

GND

+24VDC-OUT

GND

24V
AC-IN

24V
AC-IN

TB1

PWR LD1

PJ2

C3

PJ1

2S

LO

TMODULAR

I/O

2SL

OTMODULAR

I/O

VR6

7824CT7824CT

MC

LM358N

LM358N

YS101780

C4

C5

U2

VR1

R12

R6

CX2

R10

R4

R5

P2

JP2

UL5A250V

AC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

UL5A250V

AC

UL5A250V

AC

G5L-114P

-PS

OMRON

CONTACT

:

24VDC

K3

K2

4RLY IO BD.

4RLY IO BD.

V4

K4

YS101790

TB1

V1

K1

K3

U2

K4

RN1

PCF8574P

U3

CX3

U1

ULN2803A/

K2

K1

74HC04N

P1

CX2

CX1

Jumper
Setting

Advertising