Quintum Technologies Tenor Call Relay SP User Manual

Page 64

Advertising
background image

P/N 480-0048-00-10

6-7

Chapter 6: Working with SNMP

2. Type telnet in the Open box and click on Ok.

3. Click Connect> Remote System.

4. In the Host Name window, enter the IP address of the unit from which you would like to view alarms.

5. In the port window, choose telnet (port 23 is the default port for a telnet session).

6. From the TermType drop down list, select vt100.

7. Click Connect. A telnet session will be displayed. (To exit a telnet session at any time, type exit at the

prompt.)

8. Enter the same password you set via CLI.

9. At the config - MasterChassis prompt, type set snmptrapip1 <ip>. For example, type set snmptrapip1

208.226.140.12. This will assign index of 1 to indicate the first network manager being assigned to that
Call Relay SP unit and assign the IP address 208.226.140.12 as the network manager. To assign the second
snmptrap ip, type set snmptrapip2 <ip> and the third type set snmptrapip3 <ip>.

10. Repeat step 9 for each network manager (up to 3).

11. Type submit. The new IP address(es) will be submitted to the applicable Call Relay SP unit.