background image

M1-3 Overview

1-6

Verilink M1-3 User Manual

Installation

The Verilink M1-3 application module is installed after the rear
connector module. For detailed installation procedures, refer to
Chapter 3 of

the

AS3000: The Basics

manual.

WARNING

Do not install the M1-3 with non-AS3000 equipment. Improper installation

can cause equipment damage.

M1-3 Specifications

The following specifications apply to the M1-3 application module
in the AS3000 environment.

Table 1-1

Network Specifications

Regulatory

Requirements

This product complies with the following regulatory specifications
as they apply to telecommunications equipment:

FCC—Part 15, Subpart J, Class A: Computing devices

15.810: Radiated Emission

15.812: Conducted Emission

UL 1459, 2nd Edition

CSA—C225

Network Interface

Type

DS3

Line Rate

44.736 Mbit/s

±

20 ppm

Framing

C-bit parity, M13

Line Code

B8ZS

Input Signal

-11.7 dbm to +6.2 dbm, level DS3

Output Signal

-4.7 dbm to +3.6 dbm (DSX-3 cross-connect point)

Impedance

75

± 5%

Connector

BNC female, one each for TX and RX

Internal T1 Rate

n

×

1.544 Mbit/s, where n = 1 to 28

System Timing

External T3 (BNC), Network, or Internal