M1-3 configuration options, M1-3 management, M1-3 management -1 – Verilink M1-3 (880-503136-001) Product Manual User Manual

Page 31: Chapter

Advertising
background image

Verilink M1-3 User Manual

3-1

Chapter

3

M1-3 Configuration Options

The M1-3 menu options provide module access for the following
tasks:

Node and circuit configuration

Activating and deactivating the node and circuit

Setting alarms

NOTE: The options shown in this chapter depict options displayed

through the SCM Craft interface.

M1-3 Management

The M1-3 module is designed to operate with an SCM module. The
SCM Main Menu displays the contents of the shelf slots in a
selected node. In the SCM Main Menu:

An “M” at the intersection of rows and columns designates the
shelf/slot location of an M1-3 module.

The letter “S” displays where SCM modules are located.

The letter surrounded by brackets

[ ]

designates the location

of the currently active module that can be referenced and
modified via submenus of the SCM Main Menu.

On initial log in, the brackets surround the module used as the
log-in access point (for example, the SCM).

The SCM Main Menu, option

SSSS (shelf/slot) is used to move to a

desired module in the node.

In

Figure 3-1

, the SCM Main Menu shows an M1-3 (designated by

“M”) in slot 6. From the shelf/slot command, the currently accessed
module indicated by the square brackets

[ ]

has been changed to

the M1-3 in slot 1.

The asterisk next to the “*S” indicates which SCM module is the
node master. The “A” at the beginning of the prompt indicates the
SCM you are accessing is the active SCM master.