Performance Monitoring

Verilink M1-3 User Manual

4-3

System LED

The System LED displays node communication conditions. For
example, the system LED can also turn red for a loss of clock
condition, activating a critical alarm.

Table 4-3

provides a

description of the System LED states:

Table 4-3

System LED Indicator

M1-3 Alarms

The SCM polls the various modules for alarms. If alarm reporting is
enabled for the node and for the M1-3, the SCM retrieves and sends
the alarm to the Craft interface, Node Manager, or an SNMP agent.

Alarms can be automatically sent to a specified printer by setting
up the printer address in the SCM management utilities menus.

Alarm

Indications

The alarm list displays the following:

Whenever the system powers up and any module performs a
self-test

Power supply input is lost

A default or user-designated threshold is exceeded

A Yellow Alarm is received from the network (DS1)

An unframed all-ones or alarm indication signal (AIS) is
received from the network (DS1)

There is a loss of signal (LOS) or loss of frame (LOF) (DS1/DS3)

A loopback is present

A module fails

A module is removed from the shelf

Alarm

Information

The SCM alarm listing displays the following information about the
alarms.

Figure 4-2

shows an example of an M1-3 alarm report.

Status Code

The Status Code column displays a decimal code on an ASCII
terminal.

State

Color

Alarm Class

Error Condition

Solid

Green

None

M1-3 module is okay.

Solid

Red

Critical

System failure—Check the performance status or alarm status screens.

Off

None

None

M1-3 module has no power.