M1-3 Configuration Options

3-10

Verilink M1-3 User Manual

D

FE_LUAS—Far End Local Unavailable Second. Displays a far-end

unavailable second during which the DS3 port at the far end is

not receiving data from the near-end.

E

NE_LCV—Near End Line Coding Violation. Displays a near-end

bipolar violation event or an excessive zeros event.

F

NE_LES—Near End Line Errored Seconds. Displays a second in

which one or more coding violations, or one or more Loss Of

Signal errors occurred.

G

NE_LSES—Near End Line Severely Errored Seconds. A second

during which the NE was (at any point during the second) in

the AIS (Alarm Indication Signal) state.

H

NE_PCV—Near End P-bit Coding Violation. A P-bit Parity Error

event is the occurrence of a received P-bit code on the DS3 M-

frame that is not identical to the corresponding locally-

calculated code.

I

NE_PES—Near End P-bit Errored Seconds. Displays a second

with one or more PCVs, or one or more Out-Of-Frame errors or

incoming AISs (Alarm Indication Signals).

J

NE_PSES—Near End P-bit Severely Errored Seconds. Displays a

second with 44 or more PCVs, or one or more Out-Of-Frame

errors or incoming AISs (Alarm Indication Signals).

K

NE_CCV—Near End C-bit Coding Violation. Displays the near

end count of C-bit parity errors occurring in the accumulation

interval.

L

NE_CES—Near End C-bit Errored Seconds. Displays a near-end

second with one or more CCVs, or one or more Out-Of-Frame

errors or incoming AISs (Alarm Indication Signals).

M

NE_CSES—Near End C-bit Severely Errored Seconds. Displays a

near-end second with 44 or more CCVs or one or more Out-Of-

Frame errors or incoming AISs (Alarm Indication Signals).

N

NE_SEFS—Near End Severely Errored Framing Seconds.

Displays a near end second with one or more Out-Of-Frame

defects or incoming AISs (Alarm Indication Signals).

O

NE_AISS—Near End Alarm Indication Signal. A second during

which the unit receives an all-ones (Alarm Indication Signal)

code from the network

.

P

NE_LUAS—Near End Local Unavailable Second. Displays a near-

end unavailable second during which the DS3 port at the near

end is not receiving data from the far-end.

Q

NE_LOSS—Near End Loss of Signal Second. The number of

seconds in which the unit is in a Loss-Of-Signal-Second state

.

R

NE_LOFS—Near End Loss of Frame Second. The total number

of seconds the unit was in an Loss-Of-Frame state.

X