Wavecom W61PC V7.5.0 User Manual

Page 252

Advertising
background image

242

Transmission Modes

WAVECOM Decoder W61PC/LAN Manual V7.5

Parameter hex

Value ZVEI (first data word)

Value VDEW (following data words)

0

User defined

Not used

1

Call to mobile

Call to mobile

2

Call to base station

Direct Access

3

Identification

Identification

4

Acknowledgement

Acknowledgement

5

Spare (indicate VDEW)

Sequence telegram

6

Separation call

Separation call

7

Spare

Recall

8

Priority call

Emergency call

9

Status request

Status request/response

A

Spare

Position request

B

Acknowledgement

Acknowledgement

C

Spare

Quick dialing

D

User defined

Data

E

User defined

Spare

F

Emergency call

Not used

Status for ZVEI and VDEW (STAT:)

Four bits are available. In the VDEW system these four bits indicate the number of follow-up telegrams.
The last follow-up telegram and a basic telegram without follow-up telegrams are indicated by 0xA. In
ZVEI the status bits can be used by the carrier.

Rhombic labeling (RAUTE:)

Four bits are used as additional distinction for a producer designation. The use is not determined.

Manufacturer identification (Herst:)

Two digits are used. The classification is determined by ZVEI.

In the newer VDEW system the rhombic labeling and the manufacturer identification are combined into
one field of three digits, called EVU number (EVU#:).

Call number ZVEI and VDEW (Ruf#:)

Three digits are used. The hundred-position digit is transmitted first, the one-position digit last. Group
calls are transmitted as pseudo-tetrads of '1111' (16). For a group call in the 10s range the digit repre-
senting 1s is filled with logical ‘1’. For a group call in the 100s range, the 1s and 10s digit are filled with
logical ‘1’, and for a 1000s range call all 12 bits are filled with logical ‘1’.

EVU and call number are transferred in a block of six digits. The partitioning is either 3 digits for either
items or 2 EVU digits plus 4 call number digits. The chosen variant cannot be derived from the data, so
both versions are displayed.

The following picture shows a trace of a VDEW transmission with basic telegram and a single follow-up
telegram, displaying both versions of partitioning, i.e. 3 + 3 as well as 2 + 4.

Advertising