107

Details not shown

5.

Configure the MPLS TE tunnel
Details not shown

6.

Configure RSVP-TE GR
# Configure Router A.

<RouterA> system-view

[RouterA] mpls

[RouterA-mpls] mpls rsvp-te graceful-restart

# Configure Router B.

<RouterB> system-view

[RouterB] mpls

[RouterB-mpls] mpls rsvp-te graceful-restart

# Configure Router C.

<RouterC> system-view

[RouterC] mpls

[RouterC-mpls] mpls rsvp-te graceful-restart

7.

Verify the configuration
After previous configurations, a tunnel is created between Router A and Router C. Issuing the
following command, you will see that the neighbor’s GR status is Ready.

<RouterA> display mpls rsvp-te peer

Interface GigabitEthernet3/1/1

Neighbor Addr: 10.1.1.2

SrcInstance: 880 NbrSrcInstance: 5017

PSB Count: 0 RSB Count: 1

Hello Type Sent: REQ Neighbor Hello Extension: ENABLE

SRefresh Enable: NO

Graceful Restart State: Ready

Restart Time: 120 Sec Recovery Time: 300 Sec

MPLS RSVP-TE and BFD cooperation configuration example

Network requirements

Router A and Router B are connected directly. Enable MPLS RSVP-TE BFD on the interfaces connecting the

two routers, and run OSPF on the routers to ensure reachability at the network layer.
If the physical link between Router A and Router B fails, BFD can detect the failure quickly and inform

MPLS RSVP-TE of the failure.

Figure 28 Network diagram

Advertising