Crimping, For closed-loop crimp terminal recommendations, I.3 electrical installation safety – Yaskawa CIMR-PU User Manual

Page 31

Advertising
background image

Closed-Loop Crimp Terminal Recommendations

To maintain UL/cUL approval, UL Listed closed-loop crimp terminals are specifically required when wiring the drive main

circuit terminals on models 2A0110 to 2A0415, 4A0058 to 4A1200, and 5A0041 to 5A0242. Use only the tools recommended

by the terminal manufacturer for crimping. Yaskawa recommends crimp terminals made by JST and Tokyo DIP (or equivalent)

for the insulation cap.

Table i.8

matches the wire gauges and terminal screw sizes with Yaskawa-recommended crimp

terminals, tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge

and screw size for your drive model. Place orders with a Yaskawa representative or the Yaskawa sales department.
Wire gauge values shown in bold italic are the recommended values. Refer to local codes for proper selections.

Table i.8 Closed-Loop Crimp Terminal Size

Drive Model

Wire Gauge (AWG, kcmil)

Screw

Size

Crimp

Terminal

Model Number

Tool

Insulation Cap

Model No.

Code

<1>

R/L1, S/L2, T/L3 U/T1, V/T2, W/T3

Machine No.

Die Jaw

200 V Class

2A0004

2A0006

2A0008

2A0010

14

M4

R2-4

YA-4

AD-900

TP-003

100-054-028

12

R5.5-4

TP-005

100-054-029

10

2A0012

14

14

M4

R2-4

YA-4

AD-900

TP-003

100-054-028

12

12

R5.5-4

TP-005

100-054-029

10

2A0018

14

M4

R2-4

YA-4

AD-900

TP-003

100-054-028

12

R5.5-4

TP-005

100-054-029

10

2A0021

12

M4

R5.5-4

YA-4

AD-900

TP-005

100-054-029

10

2A0030

10

M4

R5.5-4

YA-4

AD-900

TP-005

100-054-029

8

8-4

AD-901

TP-008

100-054-031

6

14-NK4

AD-902

TP-014

100-054-033

2A0040

8

8

M4

8-4

YA-4

AD-901

TP-008

100-054-031

6

6

14-NK4

AD-902

TP-014

100-054-033

2A0056

6

M6

R14-6

YA-5

AD-952

TP-014

100-051-261

4

R22-6

AD-953

TP-022

100-051-262

2A0069

4

M8

R22-8

YA-5

AD-953

TP-022

100-051-263

3

R38-8

AD-954

TP-038

100-051-264

2A0081

3

M8

R38-8

YA-5

AD-954

TP-038

100-051-264

2

2A0110

3

M8

R38-8

YA-5

AD-954

TP-038

100-051-264

2
1

1/0

R60-8

YA-5

AD-955

TP-060

100-051-265

2A0138

1

M10

R38-10

YF-1

YET-300-1

TD-321,

TD-311

TP-060

100-061-114

1/0

R60-10

100-051-266

2/0

70-10

TD-323,

TD-312

TP-080

100-054-036

2A0169

2/0

M10

70-10

YF-1

YET-300-1

TD-323,

TD-312

TP-080

100-054-036

3/0

80-10

100-051-267

4/0

R100-10

TD-324,

TD-312

TP-100

100-051-269

2A0211

1/0 × 2P

M10

R60-10

YF-1

YET-300-1

TD-321,

TD-311

TP-060

100-051-266

2/0 × 2P

70-10

TD-323,

TD-312

TP-080

100-054-036

i.3 Electrical Installation Safety

YASKAWA ELECTRIC TOEP YAIP1U 03B YASKAWA AC Drive – P1000 Safety Precautions

31

Advertising
This manual is related to the following products: