Control circuit output terminals – Yaskawa CIMR-PU User Manual

Page 37

Advertising
background image

Type

No.

Terminal Name (Function)

Function (Signal Level) Default Setting

Analog Inputs /

Pulse Train

Input

RP

Multi-function pulse train input

(Frequency reference)

• Input frequency range: 0 to 32 kHz
• Signal Duty Cycle: 30 to 70%
• High level: 3.5 to 13.2 Vdc, low level: 0.0 to 0.8 Vdc
• Input impedance: 3 kΩ

+V

Power supply for analog inputs

10.5 Vdc (max allowable current 20 mA)

24 V +24 Vdc transducer power supply for customer use 150 mA maximum capacity

A1

Multi-function analog input 1

(Frequency reference bias)

• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-01.

A2

Multi-function analog input 2

(Frequency reference bias)

• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-09.

A3

Multi-function analog input 3

(Frequency reference bias)

• -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
• 4 to 20 mA, 0 to 20 mA (input impedance: 250 Ω)
• Voltage or current input must be selected by jumper S1 and H3-05.

AC

Frequency reference common

0 V

E (G) Ground for shielded lines and option cards

u

Control Circuit Output Terminals

Table i.10

lists the output terminals on the drive. Text in parenthesis indicates the default setting for each multi-function output.

Table i.10 Control Circuit Output Terminals

Type

No.

Terminal Name (Function)

Function (Signal Level) Default Setting

Fault Relay

Output

MA

N.O.

30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A

Minimum load: 5 Vdc, 10 mA

MB

N.C. output

MC

Fault output common

Multi-Function
Digital Output

<1>

MD

N.O.

30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A

Minimum load: 5 Vdc, 10 mA

ME

N.C. Output

MF

Common (Speed agree)

M1

Multi-function digital output (During run)

30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A

Minimum load: 5 Vdc, 10 mA

M2
M3

Multi-function digital output (Zero speed)

M4

Monitor Output

FM

Analog monitor output 1 (Output frequency)

-10 to +10 Vdc, or 0 to +10 Vdc

AM

Analog monitor output 2 (Output current)

AC

Monitor common

0 V

<1> Refrain from assigning functions to digital relay outputs that involve frequent switching, as doing so may shorten relay performance life. Switching

life is estimated at 200,000 times (assumes 1 A, resistive load).

Connect a suppression diode as shown in

Figure i.13

when driving a reactive load such as a relay coil. Ensure the diode rating

is greater than the circuit voltage.

A

B

C

D

A – External power, 48 V max.

B – Suppression diode

C – Coil

D – 50 mA or less

Figure i.13 Connecting a Suppression Diode

i.3 Electrical Installation Safety

YASKAWA ELECTRIC TOEP YAIP1U 03B YASKAWA AC Drive – P1000 Safety Precautions

37

Advertising
This manual is related to the following products: