Installation 1-6
Installation and Wiring
The following describes the installation and configuration of the V7 PROFIBUS-DP Option. For detailed information please refer to the
appropriate sections of this manual or the V7 Technical Manual.
Verify Drive Operation
Connect power to the drive and verify that the drive functions properly. This includes running the drive from the operator
keypad. Refer to the V7 Technical Manual, for information on connecting and operating the drive.
Remove power from the drive and wait for the charge lamp to be completely extinguished. Wait at least five additional minutes
for the drive to be completely discharged. Measure DC bus voltage and verify that it is at a safe level.
Remove the operator keypad and terminal cover.
Remove CN2 Protective Cover and Install Mounting Bracket
Remove the plastic protective cover from the CN2 connector on the drive by cutting the three tabs as shown below. Install the option
mounting bracket and secure it to the drive with the M3x8 screw provided.
Align hole in
mounting bracket
with nib on front of
the V7 drive
Secure mounting
bracket to V7 drive
with M3x8 screw
provided
Remove the CN2
protective cover
by carefully
clipping the
three tabs
Option kit mounting
bracket
C
N
2 C
o
ver
Figure 1.2 – Remove CN2 Cover and Install Option Mounting Bracket