Verify v7 profibus-dp option operation, Installation 1-10 – Yaskawa V7 PROFIBUS-DP User Manual
Page 16

Installation 1-10
Verify V7 PROFIBUS-DP Option Operation
Apply power to the drive.
Verify that the diagnostic LEDs on the front of the V7 PROFIBUS-DP Option are in their correct state.
Table 1.4 – Correct Diagnostic LED States
LED Display
PWR
COM
ERR
WD
Content
Cause
Solid Green
Solid Green
OFF
Flashing Green
Normal
Normal communication possible.
Remove power from the drive and wait for the charge lamp to be completely extinguished. Wait at least five additional minutes
for the drive to be completely discharged. Measure the DC bus voltage and verify that it is at a safe level.
Secure the communication option to the drive, aligning the recessed screw at the top-center of the option with the threaded hole
in the mounting bracket.
Install the operator keypad and terminal cover.
Set drive parameters n003, n004 and n035 to appropriate values.
Table 1.5 – Option Specific Parameter Settings
Addr
Param
Function
Data
+/- Limits - Description
Default
0 Operator
keypad
1 Terminal
2 Serial
Communication
103h n003
Operation
Method
Selection
3
Option Card (PROFIBUS-DP Option)
1
0
Operator keypad Pot
1
Operator keypad
2 Voltage
Reference
(0-10v)
3
Current Reference (4-20 Ma)
4
Current Reference (0-20 Ma)
5
Pulse Train Reference
6 Serial
Communication
7 Multi-Function
Analog Input (0-10vdc)
8 Multi-Function
Analog
Input(4-20ma)
104h n004
Reference
Selection
9
Option Card (PROFIBUS-DP Option)
2
0
0.01 Hz (< 100hz), 0.1hz (100 Hz >=100hz)
1 0.1%
2-39 Rpm
123h
n035
Frequency Reference Unit Selection
40-3999 User
Setting
0