Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 108

Advertising
background image

Chapter 2. CLI Syntax Reference

100

3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2

6 6 0

7 7 0

8 8 0

9 9 0

10 10 0

11 20 204

12 30 190

13 40 161

14 50 136

15 60 130

16 70 112

17 80 94

18 90 80

19 100 540

20 200 95

21 300 42

22 400 11

23 500 2

24 600 2

25 700 0

26 800 0

27 900 0

28 1000 0

29 2000 0

30 3000 0

31 4000 0

32 5000 0

33 6000 0

34 7000 0

35 8000 0

36 9000 0

37 10000 0

38 10000+ 0

Note that in the example above, there is a set of 38 “Bins” (shown in the first
column) and each bin has associated with it a different Response Time
category (shown in the second column). There are no commands with
response times of 10 ms or less, and there are 204 commands with response
times between 10 ms and 20 ms (bin 11). Each time that an I/O or command
sends to a drive, the response time for that I/O increments the bin associated
with that response time.