Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 113

Advertising
background image

BBU Object Commands

www.lsi.com/channel/products

105

/cx/bbu show bootloader

The /cx/bbu show bootloader command shows the BBU's boot loader
version.

Note that the BBU bootloader version is not applicable for 9750 models.

/cx/bbu show cap

The /cx/bbu show cap command shows the battery capacity in hours.

/cx/bbu show fw

The /cx/bbu show fw command shows the BBU firmware version number.

Note that the BBU firmware version does not apply to 9750 models.

/cx/bbu show lasttest

The /cx/bbu show lasttest command shows the date the battery capacity was
last measured. If the battery capacity test has never been run, then
xx-xxx-xxxx is shown.

/cx/bbu show pcb

The /cx/bbu show pcb command shows the PCB revision number on the
BBU.

/cx/bbu show serial

The /cx/bbu show serial command shows the BBU serial number.

Note:

A battery test should be run every four weeks in order to get a reliable

estimate of battery capacity, and to determine when it needs to be replaced (an
AEN is also issued as a reminder). You can use the command /cx/bbu show
lasttest
to check the date of the last test. For information about running a test, see
“/cx/bbu test [quiet]” on page 108.

Note:

The estimated BBU capacity hours shown is based on the measurement

taken during the last test. For information about running a test, see “/cx/bbu test
[quiet]” on page 108.