Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 122

Advertising
background image

Chapter 2. CLI Syntax Reference

114

3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2

/cx/ex show pwrs

The /cx/ex show pwrs command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.

The /cx/ex show pwrs command shows a summary of power supplies with
their respective information for the specified enclosure.

The PowerSupply column lists the IDs of the power supply units, the Status
column lists the status of each power supply, the State column indicate if the
unit is ON or OFF, the Voltage and Current columns indicate whether the
voltage or current is under or over the required thresholds, and the Identify
column lists the Identify setting of the power supplies.

Example:

//localhost> /c0/e0 show pwrs

PowerSupply Status State Voltage Current Identify

--------------------------------------------------------------

pwrs0 OK on OK OK Off

pwrs1 OK on OK OK Off

/cx/ex show alarms

The /cx/ex show alarms command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.

Note that in this command, alarms can be abbreviated to alms. For example,
/cx/ex show alms.

The /cx/ex show alarms command shows a summary of the alarms within the
specified enclosure. The Alarm column lists the alarm units' IDs, the Status
column lists the status of each alarm, the State column indicates whether the
alarm unit is ON or OFF, and the Audibility column indicates whether the
alarm is Muted or Unmuted.

Example:

//localhost> /c0/e0 show alarms

Alarm Status State Audibility

---------------------------------------------------

alm0 OK OFF UNMUTE