Cx/ex show – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 118
Chapter 2. CLI Syntax Reference
110
3ware SATA+SAS RAID Controller Card CLI Guide, Version 10.2
/cx/ex/fanx set identify=on|off
/cx/ex/fanx set speed=<0|1|2|3|4|5|6|7>
/cx/ex/pwrsx show
/cx/ex/pwrsx show identify
/cx/ex/pwrsx set identify=on|off
/cx/ex/tempx show
/cx/ex/tempx show identify
/cx/ex/tempx set identify=on|off
/cx/ex/almx show
/cx/ex/almx set alarm=mute|unmute|off
/cx/ex show
The /cx/ex show command applies to 9750 and 9690SA controllers. For the
9650SE and CCU enclosure, simply drop the prepended controller name in
the command and use /ex.
The /cx/ex show command shows summary information on the specified
enclosure /cx/ex. This report consists of several parts, depending on the
available elements of the enclosures. Typically, the summary consists of the
Enclosure section listing the set of enclosures, a Fan section, a Temperature
Sensor section, a Power Supply section, a Slot section, and an Alarm
section.
Example:
//localhost> /c0/e0 show
Encl Status
---------------------------
/c0/e0 OK
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2670 Off
fan1 OK ON 1 9500 Off
fan2 OK ON 1 8540 Off
fan3 OK ON 1 2830 Off
fan4 OK ON 1 9120 Off
fan5 OK ON 1 8330 Off
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 38C(100F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off
PowerSupply Status State Voltage Current Identify
---------------------------------------------------------------------------