Cx show alarms [reverse – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 51

Advertising
background image

Controller Object Commands

www.lsi.com/channel/products

43

/c1 Verify Mode = Adaptive

/c1 Verify Rate = 1

/c1 Controller Bus Type = PCIe

/c1 Controller Bus Width = 8 lanes

/c1 Controller Bus Speed = 2.5 Gbps/lane

Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy

---------------------------------------------------------------------------

u0 RAID-6 OK - - 256K 1923.11 RiW ON

u1 RAID-5 OK - - 256K 167.588 RiW ON

u2 RAID-1 OK - - - 65.1826 RiW ON

VPort Status Unit Size Type Phy Encl-Slot Model

---------------------------------------------------------------------------

p8 OK u2 68.36 GB SAS - /c1/e0/slt0 HITACHI HUS153073VL

p9 OK u2 68.36 GB SAS - /c1/e0/slt1 HITACHI HUS153073VL

p10 OK - 68.36 GB SAS - /c1/e0/slt2 SEAGATE ST373455SS

p11 OK - 68.36 GB SAS - /c1/e0/slt3 SEAGATE ST373455SS

p12 OK u1 34.18 GB SAS - /c1/e0/slt4 HITACHI HUS151436VL

p13 OK u1 34.18 GB SAS - /c1/e0/slt5 HITACHI HUS151436VL

p14 OK u1 34.18 GB SAS - /c1/e0/slt6 HITACHI HUS151436VL

p15 OK u1 34.18 GB SAS - /c1/e0/slt7 HITACHI HUS151436VL

p16 OK u1 34.18 GB SAS - /c1/e0/slt8 HITACHI HUS151436VL

p17 OK u1 34.18 GB SAS - /c1/e0/slt9 HITACHI HUS151436VL

p18 OK - 279.39 GB SAS - /c1/e0/slt10 SEAGATE ST3300656SS

p19 OK - 279.39 GB SAS - /c1/e0/slt11 SEAGATE ST3300656SS

p20 OK - 279.39 GB SAS - /c1/e0/slt12 SEAGATE ST3300655SS

p21 OK u0 279.39 GB SAS - /c1/e0/slt13 SEAGATE ST3300655SS

p22 OK - 279.39 GB SAS - /c1/e0/slt14 FUJITSU MBA3300RC

p23 OK u0 279.39 GB SAS - /c1/e0/slt16 SEAGATE ST3300655SS

p24 OK u0 279.39 GB SAS - /c1/e0/slt17 SEAGATE ST3300655SS

p25 OK u0 279.39 GB SAS - /c1/e0/slt18 SEAGATE ST3300655SS

p26 OK u0 279.39 GB SAS - /c1/e0/slt19 SEAGATE ST3300655SS

p27 OK u0 279.39 GB SAS - /c1/e0/slt20 SEAGATE ST3300655SS

p28 OK u0 279.39 GB SAS - /c1/e0/slt21 SEAGATE ST3300655SS

p29 OK u0 279.39 GB SAS - /c1/e0/slt22 SEAGATE ST3300655SS

p30 OK u0 279.39 GB SAS - /c1/e0/slt23 SEAGATE ST3300655SS

Name OnlineState BBUReady Status Volt Temp Hours LastCapTest

---------------------------------------------------------------------------

bbu On Yes OK OK OK 136 xx-xxx-xxxx

/cx show alarms [reverse]

Asynchronous event notifications (also referred to as AENs or controller
alarms) are originated by controller firmware or an SES attached enclosure
and captured by the 3ware device drivers. These events reflect warnings,
errors, and/or informative messages. These events are stored in a finite queue
inside the kernel and can be listed by CLI and 3DM2. They are also stored in
the operating system events log.

The /cx show alarms command shows all available events on a given
controller. The default is to list the events in ascending order, that is, the

Advertising