//localhost> /c0/e0 show fans

---Speed---

Fan Status State Step RPM Identify

------------------------------------------------------------

fan0 OK ON 1 2670 Off

fan1 OK ON 1 9370 Off

fan2 OK ON 1 8540 Off

fan3 OK ON 1 2810 Off

fan4 OK ON 1 9240 Off

fan5 OK ON 1 8330 Off

/cx/ex show temp

The /cx/ex show temp command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.

The /cx/ex show temp command lists the temperature sensors in enclosure
/cx/ex and the current temperature.

The maximum temperature for successful use of a drive should be noted in the
documentation for the drive.

The TempSensor column lists the temperature sensor IDs, the Status column
lists the status of each temperature sensor, the Temperature column lists the
temperature at the sensors, and the Identify column lists the Identify setting of
the temperature sensors

Example:

//localhost> /c0/e0 show temp

TempSensor Status Temperature Identify

--------------------------------------------------------

temp0 OK 41C(105F) Off

temp1 OK 37C(98F) Off

temp2 OK 34C(93F) Off

temp3 OK 38C(100F) Off

temp4 OK 38C(100F) Off

temp5 OK 34C(93F) Off

temp6 NOT-INSTALLED - Off

temp7 NOT-INSTALLED - Off