2 charge pump/loop filter, 3 voltage control output (vco), 4 multiplication factor divider (mfd) – Motorola ColdFire MCF5281 User Manual

Page 183: 5 pll lock detection

Advertising
background image

Clock Module

Freescale Semiconductor

9-13

The feedback clock comes from one of the following:

CLKOUT in 1:1 PLL mode

VCO output divided by two if CLKOUT is disabled in 1:1 PLL mode

VCO output divided by the MFD in normal PLL mode

When the frequency of the feedback clock equals the frequency of the reference clock, the PLL is
frequency-locked. If the falling edge of the feedback clock lags the falling edge of the reference clock, the
PFD pulses the UP signal. If the falling edge of the feedback clock leads the falling edge of the reference
clock, the PFD pulses the DOWN signal. The width of these pulses relative to the reference clock depends
on how much the two clocks lead or lag each other. Once phase lock is achieved, the PFD continues to
pulse the UP and DOWN signals for very short durations during each reference clock cycle. These short
pulses continually update the PLL and prevent the frequency drift phenomenon known as dead-banding.

9.7.4.2

Charge Pump/Loop Filter

In 1:1 PLL mode, the charge pump uses a fixed current. In normal mode the current magnitude of the
charge pump varies with the MFD as shown in

Table 9-8

.

The UP and DOWN signals from the PFD control whether the charge pump applies or removes charge,
respectively, from the loop filter. The filter is integrated on the chip.

9.7.4.3

Voltage Control Output (VCO)

The voltage across the loop filter controls the frequency of the VCO output. The frequency-to-voltage
relationship (VCO gain) is positive, and the output frequency is four times the target system frequency.

9.7.4.4

Multiplication Factor Divider (MFD)

When the PLL is not in 1:1 PLL mode, the MFD divides the output of the VCO and feeds it back to the
PFD. The PFD controls the VCO frequency via the charge pump and loop filter such that the reference and
feedback clocks have the same frequency and phase. Thus, the frequency of the input to the MFD, which
is also the output of the VCO, is the reference frequency multiplied by the same amount that the MFD
divides by. For example, if the MFD divides the VCO frequency by six, the PLL is frequency locked when
the VCO frequency is six times the reference frequency. The presence of the MFD in the loop allows the
PLL to perform frequency multiplication, or synthesis.

In 1:1 PLL mode, the MFD is bypassed, and the effective multiplication factor is one.

9.7.4.5

PLL Lock Detection

The lock detect logic monitors the reference frequency and the PLL feedback frequency to determine when
frequency lock is achieved. Phase lock is inferred by the frequency relationship, but is not guaranteed. The
LOCK flag in the SYNSR reflects the PLL lock status. A sticky lock flag, LOCKS, is also provided.

Table 9-8. Charge Pump Current and MFD in Normal Mode Operation

Charge Pump Current

MFD

1X

0

MFD < 2

2X

2

MFD < 6

4X

6

MFD

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3

Advertising
This manual is related to the following products: