ColdFire Core

Freescale Semiconductor

2-17

All ColdFire processors inhibit interrupt sampling during the first instruction of all exception handlers.
This allows any handler to disable interrupts effectively, if necessary, by raising the interrupt mask level
contained in the status register. In addition, the ISA_A+ architecture includes an instruction (STLDSR)
that stores the current interrupt mask level and loads a value into the SR. This instruction is specifically
intended for use as the first instruction of an interrupt service routine that services multiple interrupt
requests with different interrupt levels. For more details, see ColdFire Family Programmer’s Reference
Manual
.

2.3.3.1

Exception Stack Frame Definition

Figure 2-16

shows exception stack frame. The first longword contains the 16-bit format/vector word (F/V)

and the 16-bit status register, and the second longword contains the 32-bit program counter address.

The 16-bit format/vector word contains three unique fields:

A 4-bit format field at the top of the system stack is always written with a value of 4, 5, 6, or 7 by
the processor, indicating a two-longword frame format. See

Table 2-6

.

There is a 4-bit fault status field, FS[3:0], at the top of the system stack. This field is defined for
access and address errors only and written as zeros for all other exceptions. See

Table 2-7

.

32–47

0x080–0x0BC

Next

Trap # 0-15 instructions

48–63

0x0C0–0x0FC

Reserved

64–255

0x100–0x3FC

Next

Device-specific interrupts

1

Fault refers to the PC of the instruction that caused the exception. Next refers to the PC
of the instruction that follows the instruction that caused the fault.

31 30 29 28

27

26

25 24 23 22 21 20 19 18

17

16

15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

SSP

Format

FS[3:2]

Vector

FS[1:0]

Status Register

+ 0x4

Program Counter

Figure 2-16. Exception Stack Frame Form

Table 2-6. Format Field Encodings

Original SSP @ Time

of Exception, Bits 1:0

SSP @ 1st

Instruction of

Handler

Format Field

00

Original SSP - 8

0100

01

Original SSP - 9

0101

10

Original SSP - 10

0110

11

Original SSP - 11

0111

Table 2-5. Exception Vector Assignments (continued)

Vector

Number(s)

Vector

Offset (Hex)

Stacked

Program

Counter

Assignment

MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3