6. DISPLAY AND OPERATION

The following table lists the servo statuses that may be shown:

Name

Symbol

Unit

Description

Display

Range

Cumulative feedback
pulses

C

pulse

Feedback pulses from the servo motor encoder are counted and
displayed. The value in excess of

±

9999 is counted, bus since the

servo amplifier display is four digits, it shows the lower four digits of
the actual value. Press the "SET" button to reset the display value to
zero.

9999

to

9999

Servo motor speed

r

r/min

The servo motor speed is displayed. When the servo motor is rotating
in the reverse direction, the decimal points in the upper 3 digits are
lit. The value rounded off is displayed in

×

0.1r/min.

6000

to

6000

Droop pulses

E

pulse

The number of droop pulses in the deviation counter is displayed.
When the servo motor is rotating in the reverse direction, the
decimal points in the upper 3 digits are lit.
Since the servo amplifier display is four digits, it shows the lower
four digits of the actual value.

9999

to

9999

Cumulative command
pulses

P

pulse

The position command input pulses are counted and displayed. As
the value displayed is not multiplied by the electronic gear, it may
not match the indication of the cumulative feedback pulses. The
value in excess of

±

9999 is counted, but since the servo amplifier

display is four digits, it shows the lower four digits of the actual
value. Press the "SET" button to reset the display value to zero.
When the servo motor is rotating in the reverse direction, the
decimal points in the upper 3 digits are lit.

9999

to

9999

Command pulse
frequency

n

kpps

The frequency of the position command input pulses is displayed.
The value displayed is not multiplied by the electronic gear. When
the servo motor is rotating in the reverse direction, the decimal
points in the upper 3 digits are lit.

500

to

500

Analog speed
command voltage
Analog speed limit
voltage

F

V

(1)Torque control mode

Analog speed limit (VLA) voltage is displayed.

(2)Speed control mode

Analog speed command (VC) voltage is displayed.

10.00

to

10.00

Analog torque
command voltage
Analog torque limit
voltage

U

V

(1)Position control mode, speed control mode

Reverse rotation analog torque limit (TLA) voltage is displayed.

Indication range:

10 to +10V.

(2)Torque control mode

Reverse rotation analog torque command (TLA) voltage is

displayed.

Indication range: 0 to +10V

Refer to

the

Descrip-

tion

column.

Regenerative load
ratio

L

%

The ratio of regenerative power to permissible regenerative power is
displayed in %.

0

to

100

Effective load ratio

J

%

The continuous effective load torque is displayed.
The effective value is displayed relative to the rated torque of 100%.

0

to

300

Peak load ratio

b

%

The maximum torque generated during acceleration/deceleration,
etc.
The highest value in the past 15 seconds is displayed relative to the
rated torque of 100%.

0

to

400

Within one-revolution
position

Cy

pulse

Position within one revolution is displayed in encoder pulses.
The value returns to 0 when it exceeds the maximum number of
pulses.

0

to

8191

Multi-revolution
counter

LS

rev

The value of the multi-revolution counter is displayed.
Since the servo amplifier display is four digits, it shows the lower
four digits of the actual value.

32768

to

32767

Load inertia moment
ratio

dc

0.1

Times

The estimated ratio of the load inertia moment to the servo motor
shaft inertia moment is displayed.

0

to

1000