3 - 44

3. SIGNALS AND WIRING

(c) Alarm occurrence

Servo motor speed

ON

OFF

Base circuit

Electromagnetic
brake(CNP2-9)

Invalid(ON)

Valid(OFF)

Trouble (ALM)

No(ON)

Yes(OFF)

Dynamic brake

Dynamic brake
Electromagnetic brake

Electromagnetic brake
operation delay time(10ms)

Electromagnetic brake

(d) Main circuit power off

When main circuit power switches off, the undervoltage alarm (A.10) occurs and the operation
timing is as shown in (c) of this section.

(e) Control circuit power off

10ms

ON

OFF

Electromagnetic brake

Servo motor speed

Control power
(P24L)

Coasting

(3) Release of electromagnetic brake

To release the electromagnetic brake when main circuit power is off, use the output signal forced
output (refer to Section 6.7).
The electromagnetic brake can be released by turning on the electromagnetic brake power B1 (CNP2-
9).