Signals and wiring – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 41

Advertising
background image

3 - 16

3. SIGNALS AND WIRING

Control

Mode

Signal

Symbol

Connec-

tor Pin

No.

Functions/Applications

I/O

Division

P

S

T

To use this signal, set †††1 in parameter No. 49.
This signal is output when an alarm occurs. When there is no
alarm, respective ordinary signals (RD, INP, SA, ZSP) are output.
Alarm codes and alarm names are listed below:

(Note) Alarm Code

CN1B

19 Pin

CN1A

18 Pin

CN1A

19 Pin

Alarm

Display

Name

8888

Watchdog

A. 11

Board error 1

A. 12

Memory error 1

A. 13

Clock error

A. 15

Memory error 2

A. 17

Board error 2

A. 18

Board error 3

A. 37

Parameter error

0

0

0

A. 8E RS-232C error

0

0

1

A. 33

Overvoltage

0

1

0

A. 10

Undervoltage

A. 50

Overload 1

0

1

1

A. 51

Overload 2

A. 24

Motor output ground fault

1

0

0

A. 32

Overcurrent

A. 31

Overspeed

A. 35

Command pulse frequency
alarm

1

0

1

A. 52

Error excessive

A. 16

Encoder error 1

1

1

0

A. 20

Encoder error 2

Alarm code

CN1A

19

CN1A

18

CN1B

19

Note.0: OFF (Pin-SG open)

1: ON (Pin-SG shorted)

DO

1

∆ ∆ ∆

Advertising