2 auxiliary equipment, 1 recommended wires, 2 circuit protector – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 152: Options and auxiliary equipment

Advertising
background image

12 - 10

12. OPTIONS AND AUXILIARY EQUIPMENT

12.2 Auxiliary Equipment

Always use the devices indicated in this section or equivalent. To comply with the EN Standard or UL/C-
UL Standard, use the products which conform to the corresponding standard.

12.2.1 Recommended wires

(1) Wires for power supply wiring

The following diagram shows the wires used for wiring. Use the wires given in this section or
equivalent.

+

Servo amplifier

CNP3

CNP1

PE

24VDC power supply

AWG18 or AWG20

For the wire designed for motor cable,
refer to (2) in this section.

AWG18 or AWG20

Servo
motor

P24M

P24G

P24L

The wires used assume that they are 600V vinyl wires and the wiring distance is 30m max. If the wiring
distance is over 30m, choose the wire size in consideration of voltage drop.

(2) Wires for cables

When fabricating a cable, use the wire models given in the following table or equivalent:

Wire Model

Core Size

[mm

2

]

Number of

Cores

Core Insulation

Sheath Outline d

[mm] (Note 1)

Finishing OD

[mm]

Cable Type

Cable Model

J14B1180 (Note 2)

0.2
0.3
0.5

2 (1 pair)
2 (1 pair)

6 (3 pairs)

0.88

1.3

1.53

10.5 to 11 Motor cable

MR-JRCBL†M-H

UL20276AWG28 7pair
(BLAC)

0.08

4 (2 pairs)

0.9 to 1.27

5.6

Communication
cable

MR-JRPC98CBL†M
MR-JRPCATCBL†M

Note: d is as shown below:

d

Conductor Insulation sheath

12.2.2 Circuit protector

Servo Amplifier

Circuit protector

MR-J2-03A5

CP-30BA

Advertising