4 torque control mode, Operation – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 76

Advertising
background image

4 - 5

4. OPERATION

(6) Stop

In any of the following statuses, the servo amplifier interrupts and stops the operation of the servo
motor:
Refer to Section 3.8, (2) for the servo motor equipped with electromagnetic brake. Note that
simultaneous ON or simultaneous OFF of stroke end (LSP, LSN) OFF and forward rotation start (ST1)
or reverse rotation start (ST2) signal has the same stop pattern as described below.
(a) Servo on (SON) OFF

The base circuit is shut off and the servo motor coasts.

(b) Alarm occurrence

When an alarm occurs, the base circuit is shut off and the dynamic brake is operated to bring the
servo motor to a sudden stop.

(c) Forced stop (EMG) OFF

The base circuit is shut off and the dynamic brake is operated to bring the servo motor to a sudden
stop. Alarm A. E6 occurs.

(d) Stroke end (LSP/LSN) OFF

The servo motor is brought to a sudden stop and servo-locked. The motor may be run in the opposite
direction.

(e) Simultaneous ON or simultaneous OFF of forward rotation start (ST1) and reverse rotation start

(ST2) signals
The servo motor is decelerated to a stop.

4.2.4

Torque control mode

(1) Power on

(a) Switch off the servo on (SON) signal.

(b) When main circuit power/control circuit power is switched on, "U (torque command voltage)"

appears on the parameter unit.

(2) Test operation

Using jog operation in the "test operation mode" of the Parameter unit, make sure that the servo motor
operates. (Refer to Section 6.8.2.)

(3) Parameter setting

Set the parameters according to the structure and specifications of the machine. Refer to Chapter 5 for
the parameter definitions and to Sections 6.5 for the setting method.

Parameter

Name

Setting

Description

No. 0

Select the control mode

†††

4

First digit

: Torque control mode

No. 8

Internal speed command 1

1000

Set 1000r/min.

No. 9

Internal speed command 2

1500

Set 1500r/min.

No. 10

Internal speed command 3

2000

Set 2000r/min.

No. 11

Acceleration time constant

1000

Set 1000ms.

No. 12

Deceleration time constant

500

Set 500ms.

No. 13

S-pattern acceleration/deceleration
time constant

0

Not used

No. 14

Torque command time constant

2000

Set 2000ms

No. 28

Internal torque limit 1

50

Controlled to 50% output

After setting the above parameters, switch power off once. Then switch power on again to make the
set parameter values valid.

Advertising