39

VDC

Speed differential compensation:

Used to set the differential compensation.
Made valid when the proportion control signal is switched on.

980

0

to

1000

P x S

40

Spare

0

P x S x T

41

*DIA Input signal automatic ON selection:

Used to set automatic ON of SON, LSP and LSN.

0

Servo on signal (SON) input selection

0: Switched on/off by external input.
1: Switched on automatically in servo:
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)

Reverse rotation stroke end signal (LSN)
input selection

Forward rotation stroke end signal
(LSP) input selection

0000

0000h

to

0111h

P x S

P/S
S/T
T/P

E

xp

ansio

n p

aram

ete

rs

42

*DI1

Input signal selection 1:

Used to assign the control mode changing signal input pins and to set
the clear signal.

Control change signal (LOP) in-
put pin assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/spe-
ed, speed/torque or torque/posi-
tion change mode.

Set Value

0

1

2

Connector Pin No.

CN1B-5

CN1B-14

CN1A-8

3

CN1B-7

0

0

Clear signal (CR) selection

0: Droop pulses are cleared on the

leading edge.

1: Always cleared while on.

4

CN1B-8

5

CN1B-9

0003

0000h

to

0015h

P x S x T