Display and operation – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 108

Advertising
background image

6 - 10

6. DISPLAY AND OPERATION

(3) Default signal indications

(a) Position control mode

Lit: ON
Extinguished:OFF

Input signals

Output signals

TL (CN 1 B-9) Torque limit

PC (CN 1 B-8) Proportional control

CR (CN 1 A-8) Clear

RES (CN 1 B-14) Reset

SON(CN 1 B-5) Servo-on

LSN (CN 1 B-17) Reverse rotation stroke end

EMG (CN 1 B-15) Forced stop

LSP (CN 1 B-16) Forward rotation stroke end

RD (CN 1 A-19) Ready

LNP (CN 1 A-18) In position

ZSP (CN 1 B-19) Zero speed

TLC (CN 1 B-6) Limiting torque

DO1 (CN 1 B-4) In position

ALM (CN 1 B-18) Trouble

B1 (CNP 2-9) Electromagnetic brake

OP (CN 1 A-14) Encoder Z-phase pulse

(b) Speed control mode

SP1 (CN 1 A-8) Speed selection 1

RES (CN 1 B-14) Reset

SON (CN 1 B-5) Servo-on

LSN (CN 1 B-17) External emergency stop

EMG (CN 1 B-15) Forced stop

LSP (CN 1 B-16) Forward rotation stroke end

Lit: ON
Extinguished: OFF

RD (CN 1 A-19) Ready

SA (CN 1 A-18) Limiting speed

ZSP (CN 1 B-19) Zero speed

TLC (CN 1 B-6) Limiting torque

DO1 (CN 1 B-4) Limiting speed

ALM (CN 1 B-18) Trouble

B1 (CNP 2-9) Electromagnetic brake

OP (CN 1 A-14) Encoder Z-phase pulse

Input signals

Output signals

SP2 (CN 1 B-7) Speed selection 2

ST1 (CN 1 B-8) For ward rotation start

ST2 (CN 1 B-9) Reverse rotation start

(c) Torque control mode

RS1 (CN 1 B-9) Forward rotation selection

RS2 (CN 1 B-8) Reverse rotation selection

SP2 (CN 1 B-7) Speed selection 2

SP1 (CN 1 A-8) Speed selection 1

RES (CN 1 B-14) Reset

SON (CN 1 B-5) Servo-on

EMG (CN 1 B-15) Forced stop

Lit: ON
Extinguished: OFF

RD (CN 1 A-19) Ready

ZSP (CN 1 B-19) Zero speed

VLC (CN 1 B-6) Speed reached

ALM (CN 1 B-18) Trouble

B1 (CNP 2-9) Electromagnetic brake

Input signals

Output signals

OP (CN 1 A-14) Encoder Z-phase pulse

Advertising